Elevator Troubleshooting Guide

Elevator Fault Categories

Design, Manufacturing, and Installation Faults

After an elevator fault occurs, maintenance personnel should first identify the affected component and determine the root cause. If the issue is related to design defects, manufacturing quality, or installation errors, the system should not be adjusted blindly. Contact the manufacturer or the installation and maintenance provider before corrective work begins.

Operational Faults

These faults result from improper operation or misuse. Common examples include unauthorized manipulation of safety devices, switches, or control functions.

Component Failure Faults

Component-related failures are among the most common elevator problems. Mechanical issues may involve friction, wear, or transmission damage. Electrical failures often include burned contactor contacts, damaged relays, overheated resistors, or failed electronic components.

Elevator Troubleshooting Guide

Elevator models and control systems vary by manufacturer. The following examples are based on common elevator configurations and are intended as general troubleshooting references.

1. Elevator Does Not Start

Possible CauseCorrective Action
Main power switch is not connectedConnect the power supply and restore three-phase AC power
Supply voltage is below 330V, preventing relay operation inside the control cabinetRestore normal supply voltage and stabilize power quality
One phase of the 380V three-phase power supply is disconnectedRestore the missing power phase
Incorrect phase sequence prevents the phase relay from operatingInspect and correct the phase sequence
Car door or landing door is not fully closedInspect and close all doors properly
Door interlock switch failureRepair or replace the switch or contacts
Emergency exit door or safety door is open, or its safety switch has failedClose the safety door and inspect or replace the safety switch
Safety switch or governor switch has not reset after activationReset the switch or replace defective components
Emergency stop button remains activated or damagedReset or replace the emergency stop switch

2. Elevator Starts With Heavy Resistance and Reduced Speed

Possible CauseCorrective Action
Brake shoes do not release completelyInspect the brake circuit and adjust the brake assembly
Brake clearance is too smallAdjust brake clearance to approximately 0.5mm
DC brake coil is damaged or disconnectedInspect wiring or replace the coil
Brake DC power voltage is too lowRestore proper DC supply voltage
Poor contact in one phase of the traction motor power supplyTighten wiring connections and eliminate poor contact
Motor contactor contacts are not engaging properlyInspect or replace the contactor
Power supply voltage is too lowRestore voltage and limit voltage drop within 5%
Gear reducer lubrication failure or bearing clearance problemRepair the reducer and replace lubricant
Guide rails are misaligned or looseRealign guide rails and correct joint displacement

3. Traction Rope Slippage and Overspeed Downward Movement

Possible CauseCorrective Action
Brake torque is insufficientInspect and readjust the brake system
Counterweight is too lightRebalance the counterweight system
Counterweight is too heavyPerform balance correction
Elevator car is overloadedReduce load and operate within rated capacity
Excessive lubrication on traction sheave or ropesRemove excess lubricant
Insufficient rope wrap angle on the traction sheaveAdjust guide pulley position to increase wrap angle
Traction sheave groove wear or incorrect groove profileRe-machine or replace the traction sheave
Governor or safety gear fails to operateRepair or replace defective safety components

4. Elevator Shows Upward Direction but Does Not Move Up

Possible CauseCorrective Action
Faulty floor selection button or up relayInspect and replace defective relays, switches, or wiring
Upward limit switch does not resetInspect directional contactors and limit switches

5. Elevator Shows Downward Direction but Does Not Move Down

Possible CauseCorrective Action
Faulty floor selection button or down relayInspect and replace defective relays, switches, or wiring
Downward limit switch does not resetInspect directional contactors and limit switches

6. Elevator Runs in the Opposite Direction After Power Restoration

Possible CauseCorrective Action
Incorrect external three-phase power sequence and no phase protection device installedCorrect the phase sequence or install a phase protection device

7. Dual-Speed Elevator Cannot Operate at Low Speed

Possible CauseCorrective Action
Slow-speed contactor failureRepair or replace the contactor
Switching distance between high and low speed is too shortAdjust switching distance and selector alignment
Reed switch failureReplace the reed switch
Directional relay or floor relay does not releaseInspect and replace defective relays

8. Friction Noise During Elevator Operation

Possible CauseCorrective Action
Guide shoe liner wearReplace the liner and adjust guide shoe pressure
Foreign objects inside guide shoesRemove debris
Safety gear clearance is too smallAdjust clearance according to manufacturer specifications
Door vane rubs against landing sillInspect car alignment and adjust if necessary
Uneven wear on traction sheave groovesRe-machine or replace the sheave
Uneven tension among wire ropesReplace damaged ropes and rebalance tension
Dirt or debris on guide railsClean and lubricate guide rails
Excessive clearance between guide railsAdjust guide shoes to proper clearance

9. Elevator Leveling Problems

Possible CauseCorrective Action
Insufficient braking forceAdjust brake spring pressure and brake clearance
Excessive braking forceReadjust brake spring pressure
Counterweight imbalanceRebalance the counterweight system
Low leveling accuracy due to insufficient regenerative brakingAdjust low-speed switching settings
Incorrect leveling sensor positionAdjust sensor and leveling plate distance
Burned contactor contacts or residual magnetismReplace contacts or coils
Elevator requires repeated re-levelingAdjust brake torque and leveling sensor clearance
Reed switch failureReplace the reed switch
Brake malfunctionInspect and adjust the brake system

10. Elevator Door Opening and Closing Problems

Possible CauseCorrective Action
Door operator motor failureRepair or replace the motor
Door open limit switch fails to resetInspect and restore switch operation
Door contactor failureReplace the contactor
Door relay does not energizeInspect relays and control wiring
Door closing motor or contactor failureRepair or replace defective components
Door closing limit switch does not resetInspect and correct switch operation
Door movement becomes slow or unstableAdjust resistance value or inspect slipping belts and pulleys
Door rollers are wornReplace rollers and adjust guide rails
Debris inside door sill trackClean the sill track
Door safety edge failsRepair or replace the microswitch or transmission mechanism

11. Floor Selection Faults

Possible CauseCorrective Action
Elevator skips selected floorsReplace faulty selector relays or adjust selector contacts
Elevator stops at unselected floorsInspect relay contacts inside the speed control circuit
Floor buttons fail or do not resetInspect wiring, relays, and button alignment
Isolation diode connection errorCorrect or replace the diode

12. Governor and Safety Gear Faults

Possible CauseCorrective Action
Governor activates unexpectedlyInspect governor springs and rotating shaft lubrication
Safety gear activates below rated speedRecalibrate governor activation speed
Guide rail displacement reduces safety gear clearanceRealign and correct guide rail installation
Safety gear does not activate during overspeedInspect governor, wire rope, and linkage mechanism

13. Signal Lights Do Not Illuminate

Possible CauseCorrective Action
Burned lampReplace the lamp
Loose or disconnected wiringTighten and reconnect wiring points

14. Main Fuse Frequently Blows

Possible CauseCorrective Action
Incorrect fuse ratingReplace with properly rated fuse
Contactor sticking or poor contactRepair or replace the contactor
Excessive starting or braking timeAdjust acceleration and braking settings
Loose resistor or reactor terminalsTighten terminal connections

15. Partial Circuit Fuse Frequently Blows

Possible CauseCorrective Action
Circuit grounding faultInspect insulation and eliminate grounding points
Relay insulation breakdownImprove insulation or replace the relay

Three-Phase Induction Motor Troubleshooting Guide

1. Motor Does Not Start

Possible CauseCorrective Action
Overcurrent relay setting is too lowIncrease the relay setting appropriately
Excessive load or mechanical blockageReduce the load and inspect the mechanical transmission system
Severe bearing wear causes uneven air gap and rotor lockingInspect and replace bearings
Incorrect slot matching between stator and rotorAdjust rotor diameter or rewind the rotor according to specifications

2. Motor Speed Drops Under Load

Possible CauseCorrective Action
Excessive loadReduce the operating load
Supply voltage is below the rated valueInspect and restore the correct voltage

3. Motor Housing Becomes Electrically Live

Possible CauseCorrective Action
Moisture inside motor windings or insulation agingDry the windings or replace severely aged insulation
Metal debris inside stator slots damages insulationRemove debris and repair damaged insulation
Winding ends contact the motor housingApply insulation varnish and install insulating material
Slot insulation damage at stator core endsRepair insulation and dry the windings

4. Abnormal Motor Noise

Possible CauseCorrective Action
Rotor and stator rubbing against each otherCorrect the air gap and inspect bearings
Single-phase operation causes humming noiseInspect fuses and switch contacts
Rotor rubs against insulation paperTrim damaged insulation paper
Bearing lubrication failureClean and lubricate bearings
Bearing damageReplace bearings

5. Motor Vibration

Possible CauseCorrective Action
Rotor imbalanceRebalance the rotor
Bent shaftStraighten or replace the shaft
Broken rotor conductor barsPerform short-circuit testing and repair defects
Uneven air gap creates magnetic pullAdjust the air gap evenly

6. Bearing Overheating

Possible CauseCorrective Action
Bearing damageReplace the bearing
Improper bearing fit on the shaftCorrect the shaft tolerance
Loose or slow oil ring movement in sleeve bearingRepair or replace the oil ring
End cover or bearing cover misalignmentReinstall and align the covers properly

7. Excessive Motor Temperature or Smoke

Possible CauseCorrective Action
Cooling air passages are blockedRemove dust and oil contamination
Supply voltage is too high or too lowInspect and adjust the voltage
Incorrect winding connectionCheck winding polarity and correct wiring
Excessive air gap between stator and rotorReplace the rotor or correct the air gap
Bearing wear causes rotor misalignmentReplace worn bearings

8. Severe Three-Phase No-Load Current Imbalance

Possible CauseCorrective Action
Unequal turns in rewound stator windingsRewind the stator windings
Incorrect internal stator wiringInspect polarity and correct wiring

9. Excessive No-Load Current

Possible CauseCorrective Action
Excessive motor air gapReadjust the air gap
Insufficient winding turnsRewind the stator with the correct number of turns
Improper motor assemblyReassemble and correct rotor alignment
Lubricant has dried outReplace the lubricant

10. Low Insulation Resistance

Possible CauseCorrective Action
Moisture or water ingressDry the motor after insulation testing
Excessive dust and contamination on windingsClean and re-varnish the windings
Damaged lead wire insulationRe-insulate the wiring connections
Insulation aging caused by overheatingRe-varnish or replace the winding insulation

DC Motor Troubleshooting Guide

1. Excessive Sparking at the Brushes

Possible CauseCorrective Action
Brushes are not positioned on the neutral lineAdjust the brush holder position
Poor contact between brushes and commutatorGrind the brush contact surface and operate under light load for proper seating
Loose or misaligned brush holderTighten or realign the brush holder
Brush fit inside the holder is too tightSlightly reduce brush dimensions
Uneven or incorrect brush pressureAdjust spring pressure or replace the brush holder
Rough commutator surfaceClean or polish the commutator
Mica insulation protrudes between commutator segmentsUndercut and polish the commutator
Brushes are excessively worn or incorrect type is installedReplace with the specified brush type
Excessive load causes commutating pole saturationRestore normal operating load
Motor base is loose and causes vibrationTighten anchor bolts
Commutating pole winding short circuitInspect and repair winding insulation
Armature overheating causes loose commutator connectionsInspect voltage balance between commutator segments and reweld loose connections
Commutating pole winding polarity is reversed after maintenanceCorrect the winding polarity according to the wiring sequence
Uneven brush holder positioning causes unequal current distributionReadjust brush holder spacing evenly
Rotor balance is incorrectRebalance the rotor

2. Generator Voltage Cannot Build Up

Possible CauseCorrective Action
Residual magnetism has disappearedApply external DC excitation to restore magnetism
Incorrect rotation directionReverse the rotation direction
Field winding polarity is reversedCorrect the field winding connection
Open circuit in field windingInspect field winding and rheostat connections
Armature short circuitInspect commutator and armature winding for short circuits

3. Generator No-Load Voltage Is Below Rated Value

Possible CauseCorrective Action
Field rheostat resistance is too highReduce the rheostat resistance
Excitation current is below rated valueIncrease the excitation current
Partial short circuit in shunt field windingRepair or replace the affected winding
Brushes are not positioned on the neutral lineAdjust the brush holder position

4. Generator Voltage Drops Significantly Under Load

Possible CauseCorrective Action
Brushes are not positioned correctlyAdjust brush holder alignment
Commutating pole winding polarity is reversedReverse the winding connection
Incorrect installation sequence of main poles and commutating polesInspect magnetic pole sequence and correct installation

5. DC Motor Does Not Start

Possible CauseCorrective Action
No current supplyInspect wiring, controller connections, and fuses
Excessive loadReduce the operating load
Poor brush contactInspect spring pressure and improve brush contact
Open circuit in excitation circuitInspect and replace damaged field windings
Excessive motor speed with severe sparkingInspect field winding and speed controller connections

6. Abnormal Motor Speed

Possible CauseCorrective Action
Brushes are not positioned on the neutral lineAdjust brush holder position
Short circuit in armature or field windingInspect winding resistance and repair short circuits
Excessive resistance in field circuitInspect rheostat and field winding connections
Long-term overload operationRestore normal operating load

7. Armature or Armature Winding Smokes

Possible CauseCorrective Action
Short circuit in commutator or armatureInspect for short circuits or metal debris
Motor terminal voltage is too lowAdjust the generator output voltage
Rotor and stator rubbing against each otherInspect bearing condition and air gap alignment

8. Field Coil Overheating

Possible CauseCorrective Action
Motor speed is too lowIncrease speed to rated value
Partial short circuit in field windingReplace damaged winding
Terminal voltage exceeds rated value for extended periodsAdjust voltage to the rated value

9. Electrical Leakage at the Motor Housing

Possible CauseCorrective Action
Low insulation resistanceTest insulation resistance and dry the motor if below specification
Lead wire contacts the housingRepair the damaged wire
Damaged insulation on terminal board or windingsRestore insulation protection
Defective grounding systemRepair the grounding connection

10. Abnormal Bearing Operation

Possible CauseCorrective Action
Excessive lubrication or incorrect lubricant typeReplace with suitable lubricant